Designed to the tap-off in our Whitespace Builder. Density-first, airflow always, sized for where you're heading.
Service pack/Commercial in Confidence
Contents
The proposition
A hall is only as good as its design. We model every rack, busbar run and tap-off before anything is ordered, so the build is right the first time.
Every element placed in 2D and 3D and approved before procurement.
Density drives the design. Cooling and power are matched to the kW you'll actually run.
Pathways, power and space sized so the next expansion is an addition, not a rebuild.
A hall design, by domain
The grid the whole hall is set out on, drawn around what the room already has.
Model first
Every rack, busbar run and tap-off placed before anything is ordered.
Drag the divider. Same shell, same columns, same door: on the right, 80 cabinets in four rows, two contained cold aisles, and a busbar over every row.
Layout
Drag either slider. Illustrative layout, set out from the dimensions drawn: 600 mm cabinets twelve to a row, 1200 mm contained cold aisles, 900 mm hot aisles and 1000 mm clearance at the walls. A real hall is designed around its columns, its doors and the plant it already has.
Airflow
With nothing closing the top of the aisle, hot air comes back over the cabinet and mixes with the supply.
Hot and cold aisle containment designed in from day one: the cheapest efficiency you'll ever buy.
Designing for density
Containment, blanking and balanced airflow take conventional densities further than most halls ever push them.
How the design runs
Hover to pause. Click a stage to jump.
We measure and verify the space so the design starts from reality: structure, services, access and constraints, not a PDF of the floor plan.
Out of this stageA measured room, with the services and constraints recorded.The Whitespace Builder
Room dimensions, target racks and available power are all the Whitespace Builder needs to produce the first modelled hall.
Illustrative planning figures. Every engagement is scoped properly before we commit numbers.
The design pack
On site
The drawings the installers work from come out of the same model you approved, and the as-builts go back into it at the end.
Optronix installations, photographed on site.
Proof, redacted
An enterprise client grew from one row to a full hall over three phases. Because the end-state was designed on day one, each phase dropped in: no rework, no re-cabling, no surprises.
Client identifiers withheld; figures rounded.
Phase one: 24 cabinets, set out on the end-state grid
Our engineers
Why Optronix
Our team has designed halls for some of the largest data centre campuses in the world, where one design scales to hundreds of thousands of links and survives multiple generations. That discipline goes into every project, whatever the size.
The team drawing the hall is the team that then installs, cables and commissions it. Buildability is checked by the installation team before the pack is issued.
Layout, power, cooling and cabling are drawn together in the same model, not handed between four consultants and reconciled on site.
Design packs, rack elevations, cable schedules and as-builts in CAD and Visio, issued in the format your team already works in.
Related decks
Next step
A floor plan, a rack count and the power you have are enough to start. We will come back with a modelled layout, the containment and power design, and the budget that goes with it.